← Back to Skilled Trades All sample CVs →

Sample document — fictional candidate for illustration only. Where real organisations are named, the person, their role there and every result are invented; no connection with or endorsement by those organisations is implied. Your CV is prepared from your own record.

Santosh Jadhav
HVAC Site Supervisor — Commercial & Industrial
santosh.jadhav@email.com +91 98220 67143 Pune, Maharashtra, India
Qualifications & Safety Training
Diploma — Mechanical Engineering (MSBTE) ITI — Refrigeration & Air-Conditioner Technician (NCVT) Work at Height & Scaffold Safety Hot Work & Permit-to-Work Safe Handling of Flammable Refrigerants First Aid & CPR Fire Safety & Extinguisher Use
Professional Summary

HVAC site supervisor with 8 years in Pune, from service technician to running site teams of 25–40 on HVAC packages worth ₹6 crore–₹22 crore. Has delivered chilled-water plants, hospital OT and ICU systems and pharma cleanrooms across IT parks, healthcare and industrial sites. Zero lost-time injuries across 4.2 lakh man-hours supervised. ITI and diploma qualified; reads MEP drawings, plans manpower and material, and supports testing and commissioning through handover.

Experience
HVAC Site Supervisor Apr 2022 – Present
Pune-based MEP contracting firm (HVAC & electrical), Pune
Commercial & industrial — IT campuses, hospitals, pharma cleanrooms
  • Supervises crews of 25–40 technicians, fitters and helpers, including 3 subcontractor gangs, on HVAC packages of ₹6 crore–₹22 crore.
  • Led the ₹22 crore HVAC package for a 5.2 lakh sq ft IT office campus in Hinjewadi — 1,800 TR water-cooled chiller plant (3 × 600 TR), 64 AHUs, 11 km of ducting; handed over 12 days ahead of schedule.
  • Delivered HVAC for a 220-bed hospital in Wakad (₹9.5 crore, 660 TR): 8 operation theatres and 42 ICU beds with HEPA filtration and pressure cascades; air-change and particle-count validation passed first time.
  • Ran installation of 14,000 sq ft of ISO Class 7 and 8 cleanrooms with 18 AHUs for a pharma plant in Chakan (₹6.8 crore); room pressures held within ±2 Pa at validation.
  • Zero lost-time injuries across 4.2 lakh man-hours; runs daily toolbox talks and permits for hot work and work at height.
  • Cut duct rework from 6% to under 2% by checking shop drawings against site measurements before fabrication.
HVAC Supervisor / Senior Technician Jul 2020 – Mar 2022
HVAC installation contractor (VRF & ducted systems), Pune
  • Led teams of 8–12 on 30+ VRF projects of 20 TR–240 TR for offices, showrooms and bungalows.
  • Set the team's piping standard — nitrogen-purged brazing, 24-hour pressure test at 38 bar, vacuum to 500 microns; zero refrigerant-leak call-backs in 18 months.
HVAC Technician Jul 2018 – Jun 2020
HVAC installation contractor (VRF & ducted systems), Pune
  • Installed and serviced split, cassette and ducted units on R-32 and R-410A; attended 1,100+ service calls. Promoted to supervisor after 2 years.
Technical Skills
  • Chilled-water plants & AHUs
  • VRF systems
  • Cleanroom HVAC (ISO 14644)
  • GI ducting & insulation
  • Refrigerant piping & brazing
  • Testing, adjusting & balancing support
  • AHU & chiller panel interfacing
  • Reading MEP & shop drawings
  • Manpower & material planning
  • Daily progress reports (Excel)
  • Marathi, Hindi, English
Education & Training
Diploma in Mechanical Engineering 2019 – 2022
Government Polytechnic, Pune (MSBTE) — completed alongside full-time work, First Class
ITI — Refrigeration & Air-Conditioner Technician (NCVT) 2016 – 2018
Government ITI Aundh, Pune — 84%